Tecnologia dell'aria
ambientale e dell'aria
di processo

Ceiling installation


 

LTG Facade Ventilaton Unit Univent ® Type FVS

  • Compact design with easy connection to the facade.
  • Low-noise, virtually unperceivable sound pressure levels, e.g. 34 dB(A) at 680 m³/h and 10 dB room absorption.
  • Lower primary energy requirement compared to traditional window ventilation due to energy-efficient and usage-dependent operation with optimized fans and background control
    • low energy consumption (130 W at 680 m³/h) meets,
      SFP 1
  • Integrated compact silencer with enhanced low frequency attenuation.
  • Energy-efficient operation and thermal comfort due to optimized fans and background control.
  • High-efficient heat recovery (85 %)
  • Low power supply (0,33 W/(m³/h), meeting. SFP 1.
  • Quick and easy installation, in case of retrofitting minimum disturbance of ongoing operations.

Facade installation


Facade Fan Coil Unit Type A/C System FVM

  • Minimum space requirement even when integrated in a single-shell facade: Width 480 mm, depth 160 mm, height 2680 mm
  • Maximum space efficiency due to savings in floor heights, shaft  surfaces, and technician rooms.
  • Modular design, expandable in steps from static heating to air conditioning, thus
    • Low energy consumption thanks to the use of high-efficiency EC motors,
    • Low SFP value thanks to short air routes, low pressure losses, (<500 W/(m³/s)).
    • no unnecessary “shell & core” expenses
    • easy retrofitting
    • maximum tenant/user flexibility.

Floor Installation


 Facade Fan coil unit Type FVD

  • High thermal performances due to direct induction.

  • Extreme security against freezing by internal antifreeze control and admission of room air.
  • Low sound emissions thanks to use of silencer and quiet EC motor.

  • Low installation height.

  • High comfort due to mixed in room air.

  • Flexible use due to modular design. Dividing the system in two modules allows to meet any project requirement.

  • Length and width of the unit may be adapted to the constructional conditions.

  • High economic efficiency thanks to high-efficiency EC motor with very low power input.

 Fascade Fan Coil Unit Type FVDplus

  • High economic efficiency thanks to high-efficiency EC motor with very low power input.
  • Low SFP value thanks to short air routes (<500 W/(m³/s)).
  • Patented wind pressure control ensuring the required outside air flow in all operating and filter states.
  • High heating and cooling capacity thanks to additional secondary air fan, night-time heating operation without outside air component.
  • Extremely tight shutoff valves with automatically closing spring return motor in the event of power failure: no freezing, no uncontrolled heat losses, no fire gas transmission.
  • Extreme security against freezing by internal antifreeze control and admission of room air.
  • Good room flow thanks to patented LTG mixed/displacement flow.


 
 
 
 
© LTG Aktiengesellschaft 2006